Quick Reference
Catalyst 8510
and LightStream 1010
Hardware Information
Installing and Grounding the Chassis
Ports and Cabling
Replacing Components
Route Processor LEDs
Route Processor Port Pinouts
Port Adapter Modules
Interface Modules
Distance and Pinout Information
Pinout Information
Specifications and Regulatory Compliance Information
Quick Reference
Catalyst 8510
and LightStream 1010
Hardware Information

Installing and Grounding the Chassis
Ports and Cabling

Replacing Components

Route Processor LEDs

Route Processor Port Pinouts

Port Adapter Modules
4-port 25-Mbps 
|
|
Available Versions
Product Number
C85MS-ATM25-4P
|
Product Description
4-port ATM25 Port Adapter Module
|
12-port 25-Mbps 
|
|
Available Versions
Product Number
C85MS-ATM25-12P
|
Product Description
12-port ATM25 Port Adapter Module
|
155-Mbps 
|
|
Available Versions
Product Number
WAI-OC3-4U5
|
Product Description
4-port STS-3c/STM-1 unshielded twisted-pair (UTP-5) Port Adapter Module
|
|

|
|
Available Versions
Product Number
WAI-OC3-4MM
WAI-OC3-4SS
WAI-OC3-1S3M
WAI-OC3-4SSLR
|
Product Description
4-port STS-3c/STM-1 multi-mode fiber (MMF) Port Adapter Module
4-port STS-3c/STM-1 single-mode fiber (SMF) Port Adapter Module
OC-3 mix Port Adapter Module, 1-port single-mode (SM) intermediate-reach (IR) and 3-port multi-mode (MM) ports
4-port STS-3c/STM-1 single-mode (SM) long-reach (LR) Port Adapter Module
|
622-Mbps 
|
|
Available Versions
Product Number
WAI-OC12-1SS
|
Product Description
1-port STS-12c/STM-4c single-mode (SM) Port Adapter Module
|
|

|
|
Available Versions
Product Number
WAI-OC12-1MM
WAI-OC12-1SSLR
|
Product Description
1-port STS-12c/STM-4c multi-mode fiber (MMF) Port Adapter Module
1-port STS-12c/STM-4c single-mode (SM) long-reach (LR) Port Adapter Module
|
T1 
|
|
Available Versions
Product Number
WAI-T1-4RJ48
|
Product Description
4-port T1 (ATM) with RJ-48 interface Port Adapter Module
|
E1 
|
|
Available Versions
Product Number
WAI-E1-RJ48
|
Product Description
4-port E1 (ATM) with RJ-48 interface Port Adapter Module
|
|

|
|
Available Versions
Product Number
WAI-E1-4BNC
|
Product Description
4-port E1 (ATM) with BNC interface Port Adapter Module
|
8-port T1 and E1 IMA 
|
|
Available Versions
Product Number
C85MS-8T1-IMA
C85MS-8E1-IMA-120
|
Product Description
C8500MSR/LS1010 8-port T1 IMA Port Adapter Module
C8500MSR/LS1010 8-port E1 120-ohm IMA Port Adapter Module
|
|
4-port CES E1
and T1
|
|
Available Versions
Product Number
WAI-E1C-4BNC
|
Product Description
4-port E1 (circuit emulation) with BNC interface Port Adapter Module
|
|

|
|
Available Versions
Product Number
WAI-E1C-4RJ48
WAI-T1C-4RJ48
|
Product Description
4-port E1 (circuit emulation) with RJ-48 interface Port Adapter Module
4-port T1 (circuit emulation) with RJ-48 interface Port Adapter Module
|
CDS3 Frame Relay Port Adapter 
|
|
Available Versions
Product Number
C85MS-1DS3-FRBNC
|
Product Description
C8540 1-port Channelized DS3 Frame Relay Port Adapter Module
|
CE1 Frame Relay
|
|
Available Versions
Product Number
C85MS-4E1-4BNC
|
Product Description
C8540 4-port Channelized E1 Frame Relay Port Adapter Module
|
2-port DS3 
|
|
Available Versions
Product Number
WAI-T3-2BNC
WAI-E3-2BNC
|
Product Description
2-port DS3 Port Adapter Module
2-port E3 Port Adapter Module
|
4-port DS3 
|
|
Available Versions
Product Number
WAI-T3-4BNC
WAI-E3-4BNC
|
Product Description
4-port DS3 Port Adapter Module
4-port E3 Port Adapter Module
|
Interface Modules
ATM Router Module
|
Available Versions
Product Number
|
Product Description
|
|

|
C8510-ARM-64K
|
C8510 ATM Router Module 64K
|
|
|
Gigabit Ethernet
|
|
1-port

|
C85GE-1X-16K
C85GE-1X-64K
|
C8510 1-port Gigabit Ethernet 16K
C8510 1-port Gigabit Ethernet 64K
|
|
|
Fast Ethernet
|
|
8-port

|
C85FE-16T-16K
C85FE-16T-64K
C85FE-16TACL-16K
C85FE-16TACL-64K
C85FE-16F-16K
C85FE-16F-64K
C85FE-16FACL-16K
C85FE-16FACL-64K
|
C8540 16-port 10/100 UTP 16K
C8540 16-port 10/100 UTP 64K
C8540 16-port 10/100 UTP 16K w/ACL
C8540 16-port 10/100 UTP 64K w/ACL
C8540 16-port 100-FX MT-RJ 16K
C8540 16-port 100-FX MT-RJ 64K
C8540 16-port 100-FX MT-RJ 16K w/ACL
C8540 16-port 100-FX MT-RJ 64K w/ACL
|
Distance and Pinout Information
Maximum Transmission Distances
| Transceiver Speed |
Cable Type |
Max. Distance Between Stations |
|
10/100-Mbps Ethernet
|
Category 5 UTP
|
328 feet (100 m)
|
|
100-Mbps Ethernet
|
Multimode fiber
|
1640 feet (500 m)
|
|
1000-Mbps Ethernet
|
Multimode fiber
|
1640 feet (500 m)
|
|
1000-Mbps Ethernet
|
Single-mode fiber
|
16404 feet (5 km)
|
|
25-Mbps ATM
|
Category 5 UTP
|
328 feet (100 m)
|
|
155-Mbps ATM
|
Single-mode fiber, long reach
|
25 miles (40 km)
|
|
155-Mbps ATM
|
Multimode fiber
|
1.2 miles (2 km)
|
|
622-Mbps ATM
|
Single-mode fiber
|
9 miles (15 km)
|
|
622-Mbps ATM
|
Single-mode fiber, long reach
|
25 miles (40 km)1
|
|
622-Mbps ATM
|
Multimode fiber
|
1640 feet (500 m)
|
|
T1, 1.544-Mbps ATM
|
Category 5 twisted-pair
|
650 feet (198 m)
|
|
E1, 2.048-Mbps ATM
|
Category 5 twisted-pair and FTP (120 ohm)
|
650 feet (198 m)
|
|
E1, 2.048-Mbps ATM
|
Coaxial cable (75 ohm)
|
650 feet (198 m)
|
|
CDS3, 45-Mbps
|
Coaxial cable
|
450 feet (137 m)
|
|
CE1, 2.048-Mbps ATM
|
Category 5 twisted-pair
|
650 feet (198 m)
|
|
CES T1
|
Category 5 twisted-pair and FTP
|
650 feet (198 m)
|
|
CES E1
|
Category 5 twisted-pair and FTP (120 ohm)
|
820 feet (250 m)
|
|
CES E1
|
Coaxial cable (75 ohm)
|
650 feet (198 m)
|
|
DS3, 45-Mbps
|
Coaxial cable
|
450 feet (137 m)
|
|
E3, 34-Mbps
|
Coaxial cable
|
1299 feet (396 m)
|
| If you are attaching a short cable to the 622-Mbps long-reach port adapter, you must add 10 dB of attenuation to the cable or the transmitter might overdrive the receiver and introduce data errors. |
Pinouts to RJ-45 Connectors
The 10/100 Mbps Ethernet interface module with unshielded twisted-pair (UTP) ports supports RJ-45 connectors. The following table lists the signals for RJ-45 cable connectors.
| Pin |
Signal |
Description |
|
1
|
RxD+
|
Receive data +
|
|
2
|
RxD-
|
Receive data -
|
|
3
|
NC
|
No connection
|
|
4
|
NC
|
No connection
|
|
5
|
NC
|
No connection
|
|
6
|
NC
|
No connection
|
|
7
|
TxD+
|
Transmit data +
|
|
8
|
TxD-
|
Transmit data -
|
Pinouts to RJ-48c Connectors
The T1, E1, CES T1, and CES E1 port adapters support RJ-48c connectors. The following table lists the signals for RJ-48c connectors.
| Pin |
Description |
|
1
|
Receive ring
|
|
2
|
Receive tip
|
|
3
|
No connection
|
|
4
|
Transmit ring
|
|
5
|
Transmit tip
|
|
6
|
No connection
|
|
7
|
No connection
|
|
8
|
No connection
|
Pinout Information
96-Pin Molex to 12 Unshielded RJ-45 Connectors
The 25-Mbps port adapter supports a 96-pin Molex to 4 unshielded RJ-45 connectors. The following table lists the signals for the 96-pin Molex connector.
| Signal |
Molex Pin No. |
RJ-45 Port No. |
RJ-45 Pin No. |
Description |
|
RXA3
|
1
|
3
|
1
|
Receive data +
|
|
RXB3
|
2
|
3
|
2
|
Receive data -
|
|
GND
|
3
|
NC
|
NC
|
No connection
|
|
GND
|
4
|
NC
|
NC
|
No connection
|
|
TXA3
|
5
|
3
|
7
|
Transmit data +
|
|
TXB3
|
6
|
3
|
8
|
Transmit data -
|
|
GND
|
7
|
NC
|
NC
|
No connection
|
|
GND
|
8
|
NC
|
NC
|
No connection
|
|
RXA7
|
9
|
7
|
1
|
Receive data +
|
|
RXB7
|
10
|
7
|
2
|
Receive data -
|
|
GND
|
11
|
NC
|
NC
|
No connection
|
|
GND
|
12
|
NC
|
NC
|
No connection
|
|
TXA7
|
13
|
7
|
7
|
Transmit data +
|
|
TXB7
|
14
|
7
|
8
|
Transmit data -
|
|
GND
|
15
|
NC
|
NC
|
No connection
|
|
GND
|
16
|
NC
|
NC
|
No connection
|
|
RXA11
|
17
|
11
|
1
|
Receive data +
|
|
RXB11
|
18
|
11
|
2
|
Receive data -
|
|
GND
|
19
|
NC
|
NC
|
No connection
|
|
GND
|
20
|
NC
|
NC
|
No connection
|
|
TXA11
|
21
|
11
|
7
|
Transmit data +
|
|
TXB11
|
22
|
11
|
8
|
Transmit data -
|
|
GND
|
23
|
NC
|
NC
|
No connection
|
|
GND
|
24
|
NC
|
NC
|
No connection
|
|
RXA10
|
25
|
10
|
1
|
Receive data +
|
|
RXB10
|
26
|
10
|
2
|
Receive data -
|
|
GND
|
27
|
NC
|
NC
|
No connection
|
|
GND
|
28
|
NC
|
NC
|
No connection
|
|
TXA10
|
29
|
10
|
7
|
Transmit data +
|
|
TXB10
|
30
|
10
|
8
|
Transmit data -
|
|
GND
|
31
|
NC
|
NC
|
No connection
|
|
GND
|
32
|
NC
|
NC
|
No connection
|
|
RXA6
|
33
|
6
|
1
|
Receive data +
|
|
RXB6
|
34
|
6
|
2
|
Receive data -
|
|
GND
|
35
|
NC
|
NC
|
No connection
|
|
GND
|
36
|
NC
|
NC
|
No connection
|
|
TXA6
|
37
|
6
|
7
|
Transmit data +
|
|
TXB6
|
38
|
6
|
8
|
Transmit data -
|
|
GND
|
39
|
NC
|
NC
|
No connection
|
|
GND
|
40
|
NC
|
NC
|
No connection
|
|
TXB2
|
41
|
2
|
8
|
Transmit data -
|
|
TXA2
|
42
|
2
|
7
|
Transmit data +
|
|
GND
|
43
|
NC
|
NC
|
No connection
|
|
GND
|
44
|
NC
|
NC
|
No connection
|
|
RXB2
|
45
|
2
|
2
|
Receive data -
|
|
RXA2
|
46
|
2
|
1
|
Receive data +
|
|
GND
|
47
|
NC
|
NC
|
No connection
|
|
RXA6
|
48
|
NC
|
NC
|
No connection
|
|
RXA1
|
49
|
1
|
1
|
Receive data +
|
|
RXB1
|
50
|
1
|
2
|
Receive data -
|
|
GND
|
51
|
NC
|
NC
|
No connection
|
|
GND
|
52
|
NC
|
NC
|
No connection
|
|
TXA1
|
53
|
1
|
7
|
Transmit data +
|
|
TXB1
|
54
|
1
|
8
|
Transmit data -
|
|
GND
|
55
|
NC
|
NC
|
No connection
|
|
GND
|
56
|
NC
|
NC
|
No connection
|
|
RXA4
|
57
|
4
|
1
|
Receive data +
|
|
RXB4
|
58
|
4
|
2
|
Receive data -
|
|
GND
|
59
|
NC
|
NC
|
No connection
|
|
GND
|
60
|
NC
|
NC
|
No connection
|
|
TXA4
|
61
|
4
|
7
|
Transmit data +
|
|
TXB4
|
62
|
4
|
8
|
Transmit data -
|
| Signal |
Molex Pin No. |
RJ-45 Port No. |
RJ-45 Pin No. |
Description |
|
GND
|
63
|
NC
|
NC
|
No connection
|
|
GND
|
64
|
NC
|
NC
|
No connection
|
|
RXA9
|
65
|
9
|
1
|
Receive data +
|
|
RXB9
|
66
|
9
|
2
|
Receive data -
|
|
GND
|
67
|
NC
|
NC
|
No connection
|
|
GND
|
68
|
NC
|
NC
|
No connection
|
|
TXA9
|
69
|
9
|
7
|
Transmit data +
|
|
TXB9
|
70
|
9
|
8
|
Transmit data -
|
|
GND
|
71
|
NC
|
NC
|
No connection
|
|
GND
|
72
|
NC
|
NC
|
No connection
|
|
RXA8
|
73
|
8
|
1
|
Receive data +
|
|
RXB8
|
74
|
8
|
2
|
Receive data -
|
|
GND
|
75
|
NC
|
NC
|
No connection
|
|
GND
|
76
|
NC
|
NC
|
No connection
|
|
TXA8
|
77
|
8
|
7
|
Transmit data +
|
|
TXB8
|
78
|
8
|
8
|
Transmit data -
|
|
GND
|
79
|
NC
|
NC
|
No connection
|
|
GND
|
80
|
NC
|
NC
|
No connection
|
|
TXB5
|
81
|
5
|
8
|
Transmit data -
|
|
TXA5
|
82
|
5
|
7
|
Transmit data +
|
|
GND
|
83
|
NC
|
NC
|
No connection
|
|
GND
|
84
|
NC
|
NC
|
No connection
|
|
RXB5
|
85
|
5
|
2
|
Receive data -
|
|
RXA5
|
86
|
5
|
1
|
Receive data +
|
|
GND
|
87
|
NC
|
NC
|
No connection
|
|
GND
|
88
|
NC
|
NC
|
No connection
|
|
TXB0
|
89
|
0
|
8
|
Transmit data -
|
|
TXA0
|
90
|
0
|
7
|
Transmit data +
|
|
GND
|
91
|
NC
|
NC
|
No connection
|
|
GND
|
92
|
NC
|
NC
|
No connection
|
|
RXB0
|
93
|
0
|
2
|
Receive data -
|
|
RXA0
|
94
|
0
|
1
|
Receive data +
|
|
GND
|
95
|
NC
|
NC
|
No connection
|
|
GND
|
96
|
NC
|
NC
|
No connection
|
MT-RJ Ethernet Cable Connectors
The Ethernet ports on the 100BASE-FX interface module are MT-RJ receptacles. The following table lists the signals for the MT-RJ Ethernet cable connector.
| Pin |
Signal |
Direction |
Description |
|
1
|
VeeRX
|
|
Receiver signal ground
|
|
2
|
VccRX
|
<
|
Receive power supply
|
|
3
|
SD
|
|
Signal Detect
|
|
4
|
RD-
|
<
|
Receiver data-
|
|
5
|
RD+
|
<
|
Receiver data+
|
|
6
|
VccTX
|
>
|
Transmit power supply
|
|
7
|
VeeTX
|
>
|
Transmit signal ground
|
|
8
|
Tdis
|
|
Transmit disable
|
|
9
|
TD+
|
>
|
Transmit data+
|
|
10
|
TD-
|
>
|
Transmit data-
|
Specifications and Regulatory Compliance Information
| Description |
Specifications |
|
Switch and processor capacity
|
10-Gbps shared memory, nonblocking switch fabric up to 32-KB frames
|
|
Dimensions (H x W x D)
|
Chassis: 10.4 x 17.25 x 18.4 in (26.4 x 43.8 x 46.7 cm)
Processor, switch processor, carrier module, and interface module:
1.2 x 14.4 x 16 in (3.0 x 36.6 x 40.6 cm)
Port adapter: 1.2 x 6.5 x 10 in (3.0 x 16.5 x 25.4 cm)
Power supply: 2.7 x 6.0 x 15.3 in (6.9 x 15.2 x 38.9 cm)
|
|
Weight
|
Empty chassis: 32 lb (14.51 kg)
Fully populated chassis: approximately 130 lb (58.97 kg)
AC power supply: 11 lb (4.99 kg)
DC power supply: 10 lb (4.54 kg)
|
|
Airflow
|
95 cfm through the system fan assembly
|
|
Operating temperature
|
32 to 122 F (0 to 50 C)
|
|
Nonoperating temperature
|
-40 to 167 F (-40 to 75 C)
|
|
Humidity
|
10 to 90%, noncondensing
|
|
Altitude
|
-500 to 6,500 ft (-152 to 2000 m)
|
|
Microprocessor
|
100-Mhz MIPS R4700
|
|
AC total output
|
388W maximum
|
|
AC-input voltage
|
100-127/200-240 VAC wide input with power factor correction
|
|
AC frequency
|
Auto sensing limits: 100 to 127/200 to 240 VAC, 8/4A, 50/60 Hz
|
|
AC current rating
|
8/4A with the chassis fully populated
|
|
Power supply load
|
376W maximum configuration, 200W typical with max configuration
|
|
DC voltages supplied and steady-state maximum current ratings
|
System: +5V @ 70A
+12V @ 2A
+24V @ 0.12A
Processor: +5V @ 15A
+24V @ 25mA
+12V @ 500mA
|
| Description |
Specifications |
|
Memory
|
8-MB Flash memory SIMM (upgradable to 16 MB)
64-MB DRAM
256-KB boot EPROM
128-KB SRAM
No Flash PC card installed by default (accepts 8-, 16-, or 20-MB Intel Series 2+ Flash PC cards)
|
|
Regulatory Compliance
|
CE Marking (European Union)1
UL 1950 (U.S.A.)
CSA C22.2 No. 950 (Canada)
EN60950 (European Union)
IEC60950 (International)
AS/NZS 3260 (Australia/New Zealand)
TS001 (Australia)
21CFR1040 (Laser - U.S.A.)
EN60825 (Laser - European Union)
IEC60825 (Laser - International)
FCC Part 15 (CFR 47) Class A (U.S.A.)
VCCI Class A with UTP and Class B with FTP cables (Japan)
EN55022 Class A with UTP and Class B with FTP cables (European Union)
CISPR 22 Class A with UTP and Class B with FTP cables (International)
AS/NZS 3548 Class A with UTP and Class B with FTP cables (Australia/New Zealand)
EH 55024
EH 50082-1
ET5300 386-2
ICES 003 Class A
|
| Products bear CE Marking indicating compliance with the 99/5/EC directive, which includes the following safety and EMC standards. |
Product Documentation
Catalyst 8510 CSR Documentation
http://www.cisco.com/univercd/cc/td/doc/product/l3sw/8510/index.htm
Catalyst 8510 MSR Documentation
http://www.cisco.com/univercd/cc/td/doc/product/atm/c8510/index.htm
LightStream 1010 Documentation
http://www.cisco.com/univercd/cc/td/doc/product/atm/ls1010s/index.htm
Related Web Pages
Catalyst 8500 Series
http://www.cisco.com/warp/public/cc/pd/si/casi/ca8500/index.shtml
LightStream 1010 ATM Switches
http://www.cisco.com/warp/public/cc/pd/si/lsatsi/ls1010
Layer 3 Backbone
http://www.cisco.com/warp/public/779/largeent/design/L3_backbone.html
Catalyst 8510 CSR Software
(requires CCO authorization)
http://www.cisco.com/pcgi-bin/tablebuild.pl/cat8510c